Version: 13.0

    Show / Hide Table of Contents

    Class PermissibleContinuousAxialLoadResults

    Inheritance
    System.Object
    System.MarshalByRefObject
    SMT.MastaAPIUtility.MarshalByRefObjectPermanent
    APIBase
    PermissibleContinuousAxialLoadResults
    Implements
    System.IEquatable<APIBase>
    Inherited Members
    APIBase.DisconnectFromMASTA()
    APIBase.GetProperty<T>(String)
    APIBase.SetProperty(String, Object)
    APIBase.cacheRpds
    APIBase.clearCachedRpds()
    APIBase.getNamedObjectList<TElementType>(String)
    APIBase.getExpandableProperty<TReturnType>(String)
    APIBase.callPartialMethod(String, (T1, T2)<Type, Object>[])
    APIBase.callPartialMethod<T>(String, T)
    APIBase.callPartialMethod<T>(String, (T1, T2)<Type, Object>, T)
    APIBase.callPartialMethod<T>(String, (T1, T2)<Type, Object>, (T1, T2)<Type, Object>, T)
    APIBase.callPartialMethod<T>(String, (T1, T2)<Type, Object>, (T1, T2)<Type, Object>, (T1, T2)<Type, Object>, T)
    APIBase.callPartialMethod<T1, T2>(String, (T1, T2)<Type, Object>, T1, T2)
    APIBase.getPartialProperty(String)
    APIBase.setPartialProperty(String, Object)
    APIBase.IsValid(String)
    APIBase.IsReadOnly(String)
    APIBase.isInvalid
    APIBase.DocumentationUrl()
    APIBase.ToString()
    APIBase.RunPython<T>(String, String, Object)
    APIBase.RunPythonCode<T>(String, String, Object)
    APIBase.RunPythonCode<T>(String)
    APIBase.RunPython<T>(String, String)
    APIBase.CreateObjRef(Type)
    APIBase.RunPython(String, String, Object)
    APIBase.createWrappedRange(Double, Double)
    APIBase.createWrappedVector2D(Double, Double)
    APIBase.createWrappedPosition3D(Double, Double, Double)
    APIBase.Equals(APIBase)
    APIBase.GetHashCode()
    APIBase.Equals(Object)
    SMT.MastaAPIUtility.MarshalByRefObjectPermanent.InitializeLifetimeService()
    Namespace: SMT.MastaAPI.Bearings.BearingResults.Rolling
    Assembly: SMT.MastaAPI.13.0.dll
    Syntax
    public class PermissibleContinuousAxialLoadResults : APIBase, IEquatable<APIBase>

    Fields

    _parent

    Declaration
    protected readonly APIBase _parent
    Field Value
    Type Description
    APIBase

    Properties

    AllowableAxialLoadFactor

    If the axial load exceed the radial load multiplied by this factor then this causes abnormal roller movement.

    Declaration
    public Overridable<double> AllowableAxialLoadFactor { get; }
    Property Value
    Type Description
    Overridable<System.Double>

    AllowableConstantAxialLoadNTN

    Unlike basic road ratings based on rolling fatigue, allowable axial load is determined by heat produced on the sliding surface between the ends of the rollers and rib, seizure and wear.

    Measurement: Force

    Declaration
    public double AllowableConstantAxialLoadNTN { get; }
    Property Value
    Type Description
    System.Double

    AllowableIntermittentAxialLoadNTN

    Unlike basic road ratings based on rolling fatigue, allowable axial load is determined by heat produced on the sliding surface between the ends of the rollers and rib, seizure and wear.

    Measurement: Force

    Declaration
    public double AllowableIntermittentAxialLoadNTN { get; }
    Property Value
    Type Description
    System.Double

    AllowableMomentaryAxialLoadNTN

    Unlike basic road ratings based on rolling fatigue, allowable axial load is determined by heat produced on the sliding surface between the ends of the rollers and rib, seizure and wear.

    Measurement: Force

    Declaration
    public double AllowableMomentaryAxialLoadNTN { get; }
    Property Value
    Type Description
    System.Double

    AxialLoad

    Measurement: Force

    Declaration
    public double AxialLoad { get; }
    Property Value
    Type Description
    System.Double

    CalculationMethod

    Declaration
    public CylindricalRollerMaxAxialLoadMethod CalculationMethod { get; }
    Property Value
    Type Description
    CylindricalRollerMaxAxialLoadMethod

    CapacityLubricationFactorForPermissibleAxialLoadGrease

    Factor that scales the basic static load rating to calculate a limit due to thermal effects on continuous axial load. For use when lubricated with grease.

    Declaration
    public Overridable<double> CapacityLubricationFactorForPermissibleAxialLoadGrease { get; }
    Property Value
    Type Description
    Overridable<System.Double>

    CapacityLubricationFactorForPermissibleAxialLoadOil

    Factor that scales the basic static load rating to calculate a limit due to thermal effects on continuous axial load. For use when lubricated with oil.

    Declaration
    public Overridable<double> CapacityLubricationFactorForPermissibleAxialLoadOil { get; }
    Property Value
    Type Description
    Overridable<System.Double>

    DiameterExponentFactorForPermissibleAxialLoad

    Exponent for the outer diameter to calculate a limit due to mechanical effects on continuous axial load.

    Declaration
    public Overridable<double> DiameterExponentFactorForPermissibleAxialLoad { get; }
    Property Value
    Type Description
    Overridable<System.Double>

    DiameterScalingFactorForPermissibleAxialLoad

    Factor that scales the outer diameter to calculate a limit due to mechanical effects on continuous axial load.

    Declaration
    public Overridable<double> DiameterScalingFactorForPermissibleAxialLoad { get; }
    Property Value
    Type Description
    Overridable<System.Double>

    MaximumPermissibleAxialLoadSchaeffler

    For bearings with rollers of the standard or TB design, the maximum permissible axial load is calculated from the rib strength and the security against wear. This must not be exceeded, even if F a per gives higher values.

    Measurement: Force

    Declaration
    public double MaximumPermissibleAxialLoadSchaeffler { get; }
    Property Value
    Type Description
    System.Double

    PermissibleAxialLoadDimensionFactor

    Declaration
    public Overridable<double> PermissibleAxialLoadDimensionFactor { get; }
    Property Value
    Type Description
    Overridable<System.Double>

    PermissibleAxialLoadForBriefPeriodsSKF

    An axial load should not exceed this value for more than brief periods (1000 revolutions) to avoid any risk of flange damage, also assuming that the bearing operating temperature does not increase by more than 5 degrees temporarily. This calculation is valid under normal operating conditions, defined as a difference of 60 degrees between operating and ambient temperatures, specific heat loss of 0.5 mW/mm^2, a viscosity ratio of at least 2, and a misalignment of less than 1 minute of arc.

    Measurement: Force

    Declaration
    public double PermissibleAxialLoadForBriefPeriodsSKF { get; }
    Property Value
    Type Description
    System.Double

    PermissibleAxialLoadForOccasionalPeakLoadsSKF

    The peak axial load should not exceed this value to avoid any risk of flange damage, and this load should only be considered suitable for occasional peak loads. This calculation is valid under normal operating conditions, defined as a difference of 60 degrees between operating and ambient temperatures, specific heat loss of 0.5 mW/mm^2, a viscosity ratio of at least 2, and a misalignment of less than 1 minute of arc.

    Measurement: Force

    Declaration
    public double PermissibleAxialLoadForOccasionalPeakLoadsSKF { get; }
    Property Value
    Type Description
    System.Double

    PermissibleAxialLoadingNACHI

    Since any axial loading on a cylindrical roller bearing is supported by a "sliding" action between the roller ends and flanges, allowable axial load is based on the limiting values of heat, seizure, and wear caused by this "sliding" contact.

    Measurement: Force

    Declaration
    public double PermissibleAxialLoadingNACHI { get; }
    Property Value
    Type Description
    System.Double

    PermissibleAxialLoadInternalDimensionFactor

    Declaration
    public Overridable<double> PermissibleAxialLoadInternalDimensionFactor { get; }
    Property Value
    Type Description
    Overridable<System.Double>

    PermissibleAxialLoadSchaeffler

    The permissible axial load F a per can be calculated from the hydrodynamic load carrying capacity of the contact. The axial load carrying capacity of the bearing is therefore essentially dependent on the size of the sliding surfaces between the ribs and the end faces of the rolling elements, the sliding velocity at the ribs, the lubrication of the contact surfaces, tilting of the bearing, and friction.

    Measurement: Force

    Declaration
    public double PermissibleAxialLoadSchaeffler { get; }
    Property Value
    Type Description
    System.Double

    PermissibleAxialLoadUnderShaftDeflectionSchaeffler

    Under considerable shaft deflection, the shaft shoulder presses against the inner ring rib. In combination with the active axial load, this can lead to high alternating loading of the inner ring ribs. Under a shaft deflection of up to 2 arc minutes, the permissible axial load can be estimated.

    Measurement: Force

    Declaration
    public double PermissibleAxialLoadUnderShaftDeflectionSchaeffler { get; }
    Property Value
    Type Description
    System.Double

    PermissibleContinuousAxialLoadSKF

    A continuous axial load should not exceed this value to avoid any risk of flange damage, based on a recommendation of SKF for a constantly acting load. This calculation is valid under normal operating conditions, defined as a difference of 60 degrees between operating and ambient temperatures, specific heat loss of 0.5 mW/mm^2, a viscosity ratio of at least 2, and a misalignment of less than 1 minute of arc.

    Measurement: Force

    Declaration
    public double PermissibleContinuousAxialLoadSKF { get; }
    Property Value
    Type Description
    System.Double

    RadialLoadLubricationFactorForPermissibleAxialLoadGrease

    Factor that scales the radial load to calculate a limit due to thermal effects on continuous axial load. For use when lubricated with grease.

    Declaration
    public Overridable<double> RadialLoadLubricationFactorForPermissibleAxialLoadGrease { get; }
    Property Value
    Type Description
    Overridable<System.Double>

    RadialLoadLubricationFactorForPermissibleAxialLoadOil

    Factor that scales the radial load to calculate a limit due to thermal effects on continuous axial load. For use when lubricated with oil.

    Declaration
    public Overridable<double> RadialLoadLubricationFactorForPermissibleAxialLoadOil { get; }
    Property Value
    Type Description
    Overridable<System.Double>

    SafetyFactor

    Measurement: SafetyFactor

    Declaration
    public double SafetyFactor { get; }
    Property Value
    Type Description
    System.Double

    Implements

    System.IEquatable<T>

    Extension Methods

    UtilityMethods.IsReadOnly<T>(T, Expression<Func<T, Object>>)
    UtilityMethods.IsValid<T>(T, Expression<Func<T, Object>>)
    UtilityMethods.IsMethodValid<T>(T, Expression<Func<T, Action>>)
    UtilityMethods.IsMethodReadOnly<T>(T, Expression<Func<T, Action>>)
    Back to top